Currently the fuel from the fuel pump enters into the fuel bowl through a window at the top of the needle and seat housing and exits into the float bowl through a second window after the needle opens. This exits the fuel above the fuel level causing fuel aeration in the float bowl. BLP has designed a bottom feed needle and seat that exits the fuel below the float level and drastically reduces aeration in the float bowl. This is achieved by a special designed Viton® needle that is shaped to allow the fuel to pass around the needle and exit through the bottom of the needle and seat housing.